Configuring POS Alarm Reporting

You can configure reporting of 12 different POS alarms. To do so, perform
the following tasks within interface pos <c/s/i> mode:

Alarm Report

Description

Command

Line Alarm Indication
Signal (LAIS)

Disabled by default, configures the
interface to report line alarm indication
signal errors.

To enable reporting:

pos report lais

To disable reporting:

no pos report lais

Line Remote Defect
Indication (LRDI)

Disabled by default, configures the
interface to report line remote defect
indication errors.

To enable reporting:

pos report lrdi

To disable reporting:

no pos report lrdi

Path Alarm Indication
Signal (PAIS)

Disabled by default, configures the
system to report path alarm indication
signal errors. Line terminating
equipment (LTE) send packet alarm
indication signals to alert downstream
path terminating equipment (PTE) of
defects on their incoming line signal.

To enable reporting:

pos report pais

To disable reporting:

no pos report pais

Path Loss of Pointer
(PLOP)

Enabled by default, configures the
interface to report path loss of pointer
errors. A PLOP error may result from an
invalid pointer or too many new data
flag enabled indications.

To enable reporting:

pos report plop

To disable reporting:

no pos report plop

Path Remote Defect
Indication (PRDI)

Disabled by default, configures the
interface to report path remote defect
indication errors.

To enable reporting:

pos report prdi

To disable reporting:

no pos report prdi

B2 Signal Degrade (SD) Disabled by default, configures the

interface to report when the B2 signal
degrades enough to meet or cross a
specified Bit Error Rate (BER) threshold.
The default BER threshold for B2 signal
failure is 10-6.

To enable reporting:

pos report sd-ber

To disable reporting:

no pos report sd-ber

To set the B2 Signal Degrade
threshold:

pos threshold sd-ber

<number>