Assertion Levels

151

Configuring the Power Assertion Level

You must verify the assertion level specified by the power supply vendor to
indicate fault conditions, and set the assertion levels as specified by the
vendor.

To configure the assertion level that the power supply utilizes when
indicating a fault condition, perform the following tasks:

To display the assertion levels currently configured for both AC and DC and
power supply temperature fault indications, perform the following tasks:

Task

Command

1. Enter root mode.

root

2. Set the assertion level to report

AC current faults.

aux-device ac-monitor fault-level
{active-high | active-low}

3. Set the assertion level to report

DC current faults.

aux-device dc-monitor fault-level
{active-high | active-low}

4. Set the assertion level to report

power supply temperature
faults.

aux-device ps-temp fault-level
{active-high | active-low}

Task

Command

1. Enter root mode.

root

2. Display the assertion level

currently configured for the
reporting of AC current faults.

show aux-device ac-monitor

3. Display the assertion level

currently configured for the
reporting of DC current faults.

show aux-device dc-monitor

4. Display the assertion level

currently configured for the
reporting of power supply
temperature faults.

show aux-device ps-temp