Viewing Alarm Signals Out the DB-15 Connector

You may display the current configuration of the alarm signals over the
DB-15 connector. To do this, perform the following tasks:

Example

In the following example:

A Temp Alarm, Sys Alarm, Red Alarm, Yellow Alarm and Power Alarm
signal have been configured in the past to be sent out the DB-15
connector for all associated faults.

The administrator configures a Blue Alarm signal to not be sent out the
DB-15 connector for all associated faults.

cli:192.168.208.3:root# aux-device db15 alarm blue

cli:192.168.208.3:root# show aux-device db15

Temp Alarm backplane-temp-fault enabled

processor-temp-fault enabled

ps-temp-fault enabled

fan-temp-fault enabled

Sys Alarm backplane-system-fault enabled

backplane-temp-fault enabled

backplane-power-fault enabled

local-pwr-a-fault enabled

local-pwr-b-fault enabled

red-alarm-fault enabled

ps-temp-fault enabled

ps-ac-fault enabled

ps-dc-fault enabled

fan-temp-fault enabled

fan-rotation-fault enabled

Red Alarm bits-a-fault enabled

bits-b-fault enabled

red-alarm-fault enabled

Blue Alarm blue-alarm-fault disabled

Yellow Alarm yellow-alarm-fault enabled

Power Alarm local-pwr-a-fault enabled

Task

Command

1. Enter root mode.

root

2. Display current configuration of the

alarm signals out the DB-15 connector.

show aux-device db15