Example Procedure of Upstream Configuration

The following procedure steps you through the process of configuring
upstream channel 1. An upstream configuration example for a DOCSIS cable
interface follows. The process is similar for the remaining upstream channels.

Task

Command

1. View a list of DOCSIS

interfaces that you have
installed on your chassis.

show topology | include docs

2. Enter configuration mode

for the DOCSIS interface
that you want to configure.

interface <c/s/i>

3. Display the current

configuration for the
upstream channel that you
want to configure.

show interface cable <c/s/i> upstream
[<port number>]

4. Set the channel status for

the specified upstream
channel.

upstream <port number> no shutdown
(Sets the upstream channel status to up.)

upstream <port number> shutdown
(Sets the upstream channel status to down.)

5. Set the data backoff for the

upstream channel. Valid
values:0 –15.

upstream <port number> data-backoff
<start-number> <end-number>

6. Set the range backoff for

the selected upstream
channel. Valid values:
0 – 15.

upstream <port number> range-backoff
<start-number> <end-number>