Viewing Fault Reporting Status

Each fault condition displays one of the following states.

disabled — Reporting is not specified for the fault condition. An SNMP
Trap or syslog message is not generated when the fault condition occurs.

faulted

— Fault reporting is specified. An SNMP trap or syslog message is

generated when the fault condition occurs.

okay

— Fault reporting is specified.

Use the

show

chassis-fault status

command to display the state of each

fault condition.

Example

The following example displays that faults are to be reported for the
backplane power and local power-source-a conditions. In addition, the
display indicates that faults have not occurred for the specified conditions.

cli:192.168.244.212:root# chassis-fault backplane-power

local-pwr-a

cli:192.168.244.212:root# show chassis-fault status

Chassis Fault Status

Bits A Fault disabled

Bits B Fault disabled

Backplane System Fault disabled

Backplane Temp Fault disabled

Backplane Power Fault okay

Backplane Power A Fault disabled

Backplane Power B Fault disabled

Red Alarm Fault disabled

Blue Alarm Fault disabled

Yellow Alarm Fault disabled

Processor Temp Fault disabled

Ps Temp Fault disabled

Ps AC Fault disabled

Ps DC Fault disabled

Fan Temp Fault disabled

Fan Rotation Fault disabled

Local Pwr A Fault okay

Local Pwr B Fault disabled