Cuda 12000 IP Access Switch CLI-based Administration Guide

Configuring Chassis Parameters

79

Configuration of chassis parameters is achieved using the chassis-config

command within root mode. Perform the following tasks within root mode
to configure chassis parameters:

The following example steps you through the chassis configuration process:

cli:172.16.19.10:root# show chassis-config

Chassis Number: 101

Chassis Id: 5

Cluster Id: 20

Primary Manager Slot: 13

Secondary Manager Slot: 14

Scope: Chassis

cli:172.16.19.10:root# chassis-config 101 chassisid 1

cli:172.16.19.10:root# chassis-config 101 clusterid 0

cli:172.16.19.10:root# chassis-config 101 scope cluster

cli:172.16.19.10:root# show chassis-config

Chassis Number: 101

Chassis Id: 1

Cluster Id: 0

Primary Manager Slot: 13

Secondary Manager Slot: 14

Scope: Cluster

cli:172.16.19.10:root#

Task

Command

1. Identify the chassis number.

show chassis-config

2. Configure the chassis ID.

chassis-config <chassis-number>
chassisid <1..128>

3. Configure the Cluster ID

chassis-config <chassis-number>
clusterid <number>

4. Switch the primary management

module to a secondary role,
thereby forcing the secondary
management module into the
primary role.

chassis-config <chassis-number>
manager secondary

5. Define the management scope of

the primary or secondary chassis
controller.

chassis-config <chassis-number>
scope {chassis | cluster}