Example procedure of downstream configuration – ADC CUDA 3 User Manual

Page 389

Advertising
background image

Cuda 12000 IP Access Switch CLI-based Administration Guide

Configuring the Downstream Channel

387

Example Procedure of Downstream Configuration

The following procedure steps you through the process of configuring a
DOCSIS downstream channel. An example of a DOCSIS configuration
follows:

Task

Command

1. View a list of CMTS

interfaces that you have
installed on your chassis.
You can do so by using a
combination BAS/UNIX
command.

show topology | include docs

2. Enter configuration mode

for the CMTS interface that
you want to configure.

interface cable <c/s/i>

3. Display the current

downstream configuration
for this CMTS card.

show interface cable <c/s/i> downstream

4. Set the downstream

channel status.

downstream no shutdown
(Sets the downstream channel status to up.)

downstream shutdown
(Sets the downstream channel status to
down.)

5. Set the downstream center

frequency. Acceptable
DOCSIS range: 93.0 MHz to
855 MHz.

downstream frequency <freq number>

6. Set the downstream

channel interleave depth

downstream interleave-depth
{8 | 16 | 32 | 64 | 128}