background image

Cuda 12000 IP Access Switch CLI-based Administration Guide

Configuring SNMP Access Control

173

Perform the following tasks to configure an SNMPv1 or v2c community.
Refer to the configuration example below:

Storage

Indicates how the SNMP community’s attributes
are stored. The options are:

volatile: The entry is stored in volatile
memory. The information is lost during a
system reboot.

nonvolatile (default): The entry is stored in
non-volatile memory. The information is not
lost during a system reboot.

permanent: The entry is stored in non-volatile
memory. You cannot delete the information
but you can make modifications.

readonly: The entry is stored in non-volatile
memory. You cannot delete or modify the
information.

Task

Command

1. Enter configuration mode.

root

2. Create an SNMP community

and a corresponding security
group.

snmp-server community <community
name> <security name>

3. Specify the host that has access

to the SNMP community.

snmp-server community <community
name> <security name> address
<ip-address>

4. Specify the Mask address for a

range of hosts.

snmp-server community <community
name> <security name> address
<ip-address> mask <mask address>

5. Name the SNMP context to be

used with the SNMP
community.

snmp-server community <community
name> <security name> [address
<ip-address> [mask <mask address>]]
[context <context>]

6. Display a specific SNMP

community or all SNMP
communities.

show snmp community [<community
name>]

7. Remove an SNMP community

and its security group.

no snmp-server community
<community name>

Parameter