Example 2 – ADC CUDA 3 User Manual

Page 173

Advertising
background image

Cuda 12000 IP Access Switch CLI-based Administration Guide

Configuring SNMP Access Control

171

The following example associates an existing context to the group:

root# snmp-server group alemaps v1 read public context adc

root# show snmp group

Group Context Model Level Read View Write View Notify View Storage

---------- ------- ----- ------ ----------- ----------- ----------- -----------

alemaps adc V1 NoAuth public NonVolatile

Example 2

The following example specifies the storage type for a group:

root# snmp-server group hms v3 auth storage volatile

root# show snmp group

Group Context Model Level Read View Write View Notify View Storage

---------- ------- ----- ------ ----------- ----------- ----------- -----------

hms V3 Auth v1default Volatile