Configuring Fan Unit Assertion Levels

The fan unit, by default, sends an active-low signal to TAC to report fan
temperature and rotation faults. You configure the fan unit to send an
active-high signal if so specified by the fan unit vendor.

To configure the fan unit assertion level, perform the following tasks:

To display the fan unit assertion levels currently configured for both fan
temperature and rotation fault indications, perform the following tasks:

Example

The following example displays the assertion level currently configured for
the fan temperature:

cli:192.168.208.3:root# show aux-device fan-temp

Assert Fan Temp Fault active-high

Task

Command

1. Enter configuration mode.

root

2. Set the assertion level of the

signal used to report fan
temperature faults to the
management module.

aux-device fan-temp fault-level
{active-high | active-low}

3. Set the assertion level of the

signal used to report fan
rotation faults to the
management module.

aux-device fan-rotation fault-level
{active-high | active-low}

Task

Command

1. Enter configuration mode.

root

2. Display the assertion level

currently configured for the
reporting of fan temperature
faults.

show aux-device fan-temp

3. Display the assertion level

currently configured for the
reporting of fan rotation
faults.

show aux-device fan-rotation