SkyTrak 6036 Service Manual User Manual

Page 112

Advertising
background image

Cab and Covers

4.8

Model 6036 Legacy

9. Working through the left dash panel opening, label,

disconnect and plug the load sense hose (Fig. 4-10, 1)
at the top of the steering valve. Cap the fitting on the
steering valve.

10. Disconnect the horn button wire (Fig. 4 -10, 2) from

the cab wiring harness.

Figure 4-10 Disconnect Load Sense Hose and

Horn Button Wire

11. Support the bottom of the steering valve (Fig. 4-11, 1),

and remove the four hex-flange capscrews (2) and
four lockwashers (3). Remove the steering valve
through the lower dash panel opening.

12. Remove the steering column (Fig. 4-11, 4), by

pushing it down, and removing it through the lower
dash panel opening.

Figure 4-11 Remove the Steering Column and Valve

b. Steering Column and Valve Installation

1. Install the steering column (Fig. 4-11, 4) and steering

valve (1), by inserting them through the lower dash
panel opening. Position steering valve in the cab,
with the “LS” port (5) pointing forward (away from the
operator). Secure the steering valve and column with
four hex-flange capscrews (2) and four lockwashers
(3). Torque capscrews to 13 lb/ft (18 Nm).

Note: ALWAYS use new o-rings when servicing the
vehicle.

2. Install new o-rings into the fittings. Lubricate the o-rings

with clean hydraulic oil.

3. Connect the load sense hose (Fig. 4-10, 1) to the

“LS” port at the top of the steering cylinder.

4. Connect the horn button wire (Fig. 4-10, 2) to the

cab wiring harness.