Hydraulic system – SkyTrak 6036 Service Manual User Manual

Page 233

Advertising
background image

8.17

Model 6036 Legacy

Hydraulic System

NOTE:

When checking pressures in
circuits, refer to Section 8.7,
“Hydraulic System Testing” for
correct pressure readings.

Not

OK

If the extend/retract cylinder

does not extend, check

cable connections at main

control valve.

If OK

Repair/replace cable

connections. Ensure extend/

retract section of main control

valve is functioning.

Not

OK

Check main relief pressure at

“VG” port of unloader valve.

Adjust/repair/replace relief

valve on unloader valve.

If OK

Not

OK

If the extend/retract cylinder

drifts or reacts slowly, check

the counterbalance and

pilot-operated check valves

on extend/retract cylinder.

Replace counterbalance and/

or pilot-operated check valves

on extend/retract cylinder.

Not

OK

Check pump flow.

Repair/replace pump.

Before troubleshooting any
hydraulic circuit, ALWAYS
begin by checking the
following:

1. Hydraulic oil level in the

reservoir

2. All hoses, tubes, fittings

for leaks, kinks,
interference, etc.

3. Air in the lines

Not

OK

Check packing on

extend/retract cylinder.

Repair/replace

extend/retract cylinder.

If OK

NOTE:

Refer to Section 2.5.4,
“Performance Specifications” for
approximate cylinder cycle
times. The operation of the
system function should
approximate the times listed.

Not

OK

Check the counterbalance

valve on the

extend/retract cylinder.

Replace

counterbalance valve.

If OK

Not

OK

Check packing on

extend/retract cylinder.

Repair/replace

extend/retract cylinder.

If OK