8.31

Model 6036 Legacy

Hydraulic System

NOTE:

When checking pressures in
circuits, refer to Section 8.7,
“Hydraulic System Testing” for
correct pressure readings.

Not

OK

Not

OK

If the attachment tilt cylinder

extends slowly, check cable

connections at main control

Repair/replace slave cylinder(s).

Not

OK

Check packing in attachment

tilt cylinder.

Repair/replace attachment

tilt cylinder.

If OK

Not

OK

Check the pilot-operated check

valve on the attachment tilt cylinder.

Replace pilot-operated check valve.

Repair/replace cable connections.

Ensure attachment tilt section of

main control valve is functioning.

Isolate and check each slave

cylinder for packing leaks.

If OK

Not

OK

Check main relief pressure at “VG”

port of unloader valve.

Adjust/repair/replace relief valve

on unloader valve.

If OK

Not

OK

Check differential pressure sense

valve on the unloader valve.

Adjust/replace differential pressure

sense valve on unloader valve.

If OK

If OK

If OK

Before troubleshooting any
hydraulic circuit, ALWAYS
begin by checking the
following:

1. Hydraulic oil level in the

reservoir

2. All hoses, tubes, fittings

for leaks, kinks,
interference, etc.

3. Air in the lines

Not

OK

Check pump flow.

Repair/replace pump.

NOTE:

Refer to Section 2.5.4,
“Performance Specifications” for
approximate cylinder cycle
times. The operation of the
system function should
approximate the times listed.

Not

OK

If the attachment tilt cylinder

drifts and does not hold load,

check the counterbalance valve

on the attachment tilt cylinder.

If OK

Not

OK

Check packing in attachment

tilt cylinder.

Repair/replace attachment

tilt cylinder.

Not

OK

Isolate and check packing in each

slave cylinder.

Replace counterbalance valve.

If OK

Repair/replace slave cylinder(s).

Advertising