Hydraulic system – SkyTrak 6036 Service Manual User Manual

Page 231

Advertising
background image

8.15

Model 6036 Legacy

Hydraulic System

Not

OK

Not

OK

Not

OK

Not

OK

Not

OK

Not

OK

Check pressure at front axle.

If service brakes are not

holding, check the pressure

at the brake valve.

Replace brake valve.

Check the brakes for

mechanical failure.

If OK

Replace brake valve.

If park brake fails to

hold, check the “PBG”

port on the secondary

function manifold. Should

read 0 psi.

If park brake fails to

release, check the “PBG”

port on the secondary

function manifold. Should

read 550 psi (38 bar).

Check relief valve on

secondary function

manifold.

Refer to Section 9.15,

“Switches and Solenoids.”

Not

OK

Within the front axle:

If not holding, check the park

brake springs.

If not releasing, check the

piston seals.

Install seal kit/replace

solenoid valve cartridges.

If OK

Adjust/repair/replace

relief valve.

If OK

Check solenoid valve

cartridges.

Check solenoid valves on the

secondary function manifold.

Refer to ZF Axle Repair

Manual: Model MS-T 3045,

JLG P/N 8990419

(ZF P/N 5871 550 002).

If OK

If OK

NOTE:

When checking pressures in
circuits, refer to Section 8.7,
“Hydraulic System Testing” for
correct pressure readings.

Before troubleshooting any
hydraulic circuit, ALWAYS
begin by checking the
following:

1. Hydraulic oil level in the

reservoir

2. All hoses, tubes, fittings

for leaks, kinks,
interference, etc.

3. Air in the lines

Not

OK

Check front and rear brake

discs for wear.

Refer to Model 6036 Legacy

Owners/Operators Manual.

If OK

Not

OK

Check front brake

discs for wear.

Refer to Model 6036 Legacy

Owners/Operators Manual.

If OK

Refer to ZF Axle Repair

Manual: Model MS-T 3045,

JLG P/N 8990419

(ZF P/N 5871 550 002).

Advertising