Hydraulic system – SkyTrak 6036 Service Manual User Manual

Page 239

Advertising
background image

8.23

Model 6036 Legacy

Hydraulic System

NOTE:

When checking pressures in
circuits, refer to Section 8.7,
“Hydraulic System Testing” for
correct pressure readings.

Before troubleshooting any
hydraulic circuit, ALWAYS
begin by checking the
following:

1. Hydraulic oil level in the

reservoir

2. All hoses, tubes, fittings

for leaks, kinks,
interference, etc.

3. Air in the lines

Not

OK

If OK

Repair/replace cable

connections. Ensure lift/lower

section of main control valve is

functioning.

Not

OK

Check main relief pressure at

“VG” port of unloader valve.

Adjust/repair/replace relief

valve on unloader valve.

If OK

Not

OK

Check pump flow.

Repair/replace pump.

Not

OK

Check packing on

lift/lower cylinder(s).

Repair/replace

lift/lower cylinder(s).

If OK

If the lift/lower cylinders do

not lower, check the cable

connections at the main

control valve.

NOTE:

Refer to Section 2.5.4,
“Performance Specifications” for
approximate cylinder cycle
times. The operation of the
system function should
approximate the times listed.

Not

OK

If the lift/lower cylinders drift

or react slowly, check the

counterbalance and pilot-
operated check valves on

lift/lower cylinder(s).

Replace counterbalance and/

or pilot-operated check valves

on lift/lower cylinder(s).

Not

OK

Check each

lift/lower cylinder packing.

Repair/replace

lift/lower cylinder(s).

If OK

Not

OK

Check the pilot-operated

check the valve on the lift/

lower cylinder(s).

Repair/replace pump.

Advertising