Hydraulic system – SkyTrak 6036 Service Manual User Manual

Page 241

Advertising
background image

8.25

Model 6036 Legacy

Hydraulic System

NOTE:

When checking pressures in
circuits, refer to Section 8.7,
“Hydraulic System Testing” for
correct pressure readings.

Before troubleshooting any hydraulic circuit, ALWAYS begin by checking the following:

1. Hydraulic oil level in the reservoir
2. All hoses, tubes, fittings for leaks, kinks, interference, etc.
3. Air in the lines

Not

OK

Not

OK

If the frame sway cylinder

will not sway left, drifts or

reacts slowly, check cable

connections at the main

control valve.

Replace check valves on

frame sway cylinder.

If OK

If OK

Not

OK

Inspect pilot-operated

check valves on frame

sway cylinder.

Repair/replace cable

connections. Ensure frame

sway section of main control

valve is functioning.

Check frame sway

cylinder packing.

Repair/replace frame

sway cylinder.

NOTE:

Refer to Section 2.5.4, “Performance Specifications”
for approximate cylinder cycle times. The operation
of the system function should approximate the
times listed.