Electrical system, 8 charging circuit and troubleshooting – SkyTrak 6036 Service Manual User Manual

Page 376

Advertising
background image

Electrical System

9.24

Model 6036 Legacy

9.7.8

Charging Circuit and Troubleshooting

Figure 9-15 Charging Circuit

FUEL SHUTOFF

+

-

SOLENOID

106

152

27

BATTERY

STARTER

GROUND

BATTERY

34

152

(-

40 AMP

MAIN

FUSE

(-)

(-)

(+)

(+)

ALTERNATOR

2W

5

38

38

6

6

TO

INSTRUMENT

CLUSTER

TO

IGNITION

SWITCH

BATTERY

INDICATOR

TO

INSTRUMENT

CLUSTER

HOURMETER

B+

GRD.

D+

G

H P

2S

MA8800