9.68

Model 6036 Legacy

b. Normal Operating Lights

After the engine starts, the operator’s instrument cluster
(Fig. 9 -42, 6) provides information via the following
indicators:

Fuel Level Indicator

The fuel level indicator (Fig. 9-42, 1) represents
The quantity of fuel remaining in the fuel tank.
For additional information, refer to Section
9.9.7, “Fuel Level Indicator Troubleshooting.”

Figure 9-42 Normal Operating Lights

Hourmeter Indicator

The hourmeter indicator (Fig. 9 -42, 2) displays
the total number of running hours of the vehicle.
The hourmeter only functions when the engine
is running.

c. Function

Indicator

Lights

There are three subdued or “hidden” function indicator
lights on the display panel that illuminate only when a
specific function is activated. They are:

Park Brake Indicator

The park brake indicator (Fig. 9-42, 3) illuminates
anytime the park brake switch is applied, and
the ignition key switch is in the RUN position.

High-Beam Indicator (Optional)

The high-beam indicator (Fig. 9-42, 4)
illuminates when the optional headlight switch
is placed in the HIGH-BEAM position.

Directional Light Indicator (Optional)

The directional light (turn signal) indicator
(Fig. 9-42, 5) illuminates when the optional
directional light lever is moved either to the
LEFT or RIGHT turn position.

d. Operator’s Instrument Cluster Removal

1. Disconnect the negative (-) battery cable at its

battery terminal.

2. Remove the four fasteners (Fig. 9-43, 1) securing the

right side access panel (2).

Figure 9-43 Remove the Right Side Console Access Panel

3. Unscrew the locking ring from below the instrument

cluster (Fig. 9-43, 3). Pull the instrument cluster up
and away from the cutout, and unplug the harness
connector.

OH24702

0000 00

P

MA8230

1

2

4

5

3

6

OS02602

P

OH24802

MA8260

CAUTION:

Static electricity can cause

damage to the operator’s instrument cluster.
Avoid any manner of touching (hands, tools,
etc.) the printed circuit boards and terminals.
Disconnect the negative (-) battery cable at its
battery terminal before beginning this
procedure. Failure to comply can result in dam-
age to the operator’s instrument cluster and
malfunction of the instruments and indicator
lights.