Electrical system, 8 hourmeter indicator troubleshooting – SkyTrak 6036 Service Manual User Manual

Page 408

Advertising
background image

Electrical System

9.56

Model 6036 Legacy

9.9.8

Hourmeter Indicator Troubleshooting

0000 00

P

Check circuit 38 (ORG) for

battery voltage to instrument

cluster connector.

Hourmeter indicator does

not register operating

hours.

Not

OK

Check circuit 2W (BLK) for

ground. Refer to Section

9.7.6, “Main Electrical

Schematic.”

Repair ground wire.

Not OK

Check alternator terminal D+

for battery voltage.

If

OK

If OK

Hourmeter

Indicator

MA7640

Before troubleshooting any
electrical circuit, ALWAYS
begin by checking the
following:

1. Fuses.

2. Battery for proper charge.

3. All connections relating

to circuit are clean and
tight.

4. Check instrument cluster

bulbs for proper function.

Not Used

Optional

Not OK

Replace instrument cluster.

Replace alternator.

Advertising