SkyTrak 6036 Service Manual User Manual

Page 429

Advertising
background image

9.77

Model 6036 Legacy

Electrical System

c. Inspection and Replacement

To determine the proper operation of the ignition key
switch, and using the following charts, test the wires on
the back of the switch for continuity with an ohmmeter.

Test the ignition key switch for continuity, by checking
from the ignition (BLUE) wire to each of the following
wires in each switch position. Continuity (X) should be
present as indicated in the following chart:

Test the ignition key switch for continuity, by checking
from the ignition (GREEN) wire to each of the following
wires in each switch position. Continuity (X) should be
present as indicated in the following chart:

If all wires DO NOT show proper continuity, replace the
ignition switch.

d. Ignition Switch Installation

1. Connect the ignition key switch to the cab harness

connectors.

2. Reach up and under the dash, and work the ignition

switch into the ignition switch-mounting hole on the
lower right side of the dash (Fig. 9-57, 1).

3. Align the ignition switch so that when it is in the OFF

position (Fig. 9-58), the key slot is positioned vertically
(straight up and down). Install the hex nut securing
the ignition switch to the dash. DO NOT overtighten.

4. Install the lower access panel (Fig. 9 -57, 1).

Figure 9-58 Ignition Key Switch

5. Connect the negative (-) battery cable at the

negative battery terminal.

Switch Position

Test from BLUE wire to:

OFF

RUN

START

PARK BRAKE
Wire 1 (WHT) (10 GAGE)

X

Switch Position

Test from GRN wire to:

OFF

RUN

START

CAB HARNESS
Wire 26 (RED) (10 GAGE)

X

X

Switch Position

Test from RED wire to:

OFF

RUN

START

CAB HARNESS
Wire 26A (RED)
(10 GAGE)

X

X

Switch Position

Test from YEL
(10 GAGE) wire to:

OFF

RUN

START

FUSE BOX
Wire 3C (PUR) (10 GAGE)

X

X

Switch Position

Test from YEL
(12 GAGE) wire to:

OFF

RUN

START

FUEL SHUT-OFF
SOLENOID Wire 34
(RED/BLK)

X

X

OFF

RUN

START

OT0680

Advertising