Remote programming options – AMETEK XG Family Programmable DC User Manual

Page 103

Advertising
background image



Analog Programming

(APG) and Isolated Analog Programming (ISOL)

M370430-01 Rev E

4-3

4

Remote Programming Options

Analog Monitor Signals

There are four monitor lines for analog programming the pin name and
the related APG mode, which are listed in Table 4-1. All of these lines
are provided to give analog feedback. The output from these monitor
lines is a value scaled to the Analog Programming level set for the
corresponding analog programming type. For example, the voltage
monitor and isolated voltage monitor lines are both scaled to the analog
programming level that is set in the VAP mode.

Table 4-1 Monitor Lines

Related APG Mode

Reference Line
Name

Connector

Non-Isolated Voltage Analog Programming

VOL_MON

J1.13

Isolated Voltage Analog Programming

IS_MON_VOL

J3.5

Non-Isolated Current Analog Programming

CUR_MON

J1.14

Isolated Current Analog Programming

IS_MON_CUR

J3.10

Important:

Analog control monitor lines will reflect the output of the power

supply even when the unit is not set to operate in analog programming mode.

Important:

Isolated monitor lines are only valid when isolated analog

programming modes are used for the respective voltage and current control. If
local (front panel) control is used or non-isolated APG is used, these values will
be inaccurate and should not be used for monitoring. Conversely, if isolated
APG is used, the non-isolated monitor lines will be inaccurate.