Voltage-controlled current isol setup – AMETEK XG Family Programmable DC User Manual

Page 125

Advertising
background image



Analog Programming

(APG) and Isolated Analog Programming (ISOL)

M370430-01 Rev E

4-25

4

Voltage-Controlled Current ISOL Setup

Activating ISOL Programming Current Mode

1.

Turn the 9-position mode control to the CAP position or press
the rotary adjust/Enter control if the control knob is already at
the CAP position.

is displayed on the output voltage display.

2.

Turn the rotary Adjust/Enter control to select

(voltage

source from isolated connector).

3.

Press the rotary adjust/Enter control to commit the selected

mode.

is displayed on the output voltage display.

4.

Select the input source level using the rotary adjust/Enter

control.

5.

Once the desired level has been selected, press the rotary

adjust/ Enter control to commit the change.

The display will return to the normal display.

Deactivating ISOL Current Mode

To deactivate the ISOL current mode:

1.

Turn the 9-position mode control to the VAP position or press
the rotary Adjust/Enter control if the control knob is already
at the VAP position.

2.

is displayed on the output voltage display.

3.

Turn the rotary Adjust/Enter control to select

.

4.

Press the rotary Adjust/Enter control to commit the change.

The display will return to the normal display.