Command error list – AMETEK XG Family Programmable DC User Manual

Page 333

Advertising
background image



APPENDIX B

Error Messages

M370430-01 Rev E

B-3

B

Command Error List

An error in the range [-199, -100] indicates that an IEEE 488.2 syntax
error has been detected by the instrument's parser. The occurrence of
any error in this class causes the command error bit (bit 5) in the Event
Status Register to be set.

Table B-1 Command Error List

Error
Code

Error Message Description

-100

Command error This is the generic syntax error

-102

Syntax Error An unrecognized command or data type was
encountered; for example, a string was received when the device
does not accept strings.

-108

Parameter not Allowed More parameters were received than
expected for the header; for example, the *SRE common
command only accepts one parameter, so receiving *SRE 0,1 is
not allowed.

-109

Missing Parameter Fewer parameters were received than
required for the header; for example, the *SAV common
command requires one parameter, so receiving *SAV is not
allowed.

-110

Command header error An error was detected in the header.

-113

Undefined header The header is syntactically correct, but it is
undefined for this specific device; for example, *XYZ is not
defined for any device.

-121

Invalid character in number An invalid character for the data
type being parsed was encountered; for example, an alpha in a
decimal numeric or a “9” in octal data.

-140

Character data error This error is generated when parsing a
character data element.

-150

String data error This error is generated when parsing a string
data element fails.

-151

Invalid string data A string data element was expected, but was
invalid for some reason (see IEEE 488.2, 7.7.5.2); for example,
an END message was received before the terminal quote
character.

Advertising