To access the tracking mode for entering voltage and current:

1.

Select the VOLTS or AMPS position on the 9-position mode
control. If the set point is blinking, the unit is in coarse
tracking mode.

When the VOLTS mode is selected, the voltage set point will
blink in the output voltage display.

When the AMPS mode is selected, the current set point will
blink in the output current display.

2.

Use the rotary Adjust/Enter control to adjust the set point.
Note that there is an activity time out (see Normal Display
Mode and Inactivity Timeout on page 3-6).

The adjustments you make to the set point affect the opposing
output value (voltage when in AMPS mode or current when in
VOLTS mode), which will update in the non-blinking display.

3.

Press the rotary Adjust/Enter control to enter fine adjust
tracking mode.

The set point blinks faster when the unit is in fine adjust tracking
mode.

4.

Use the rotary Adjust/Enter control to fine tune the set point.

5.

Once the set point has been selected, press the rotary
Adjust/Enter control to exit tracking mode and return to
normal display mode.

To access the select and set entry mode for the voltage and current
set points:

1.

Select VOLTS or AMPS position on the 9-position mode
control.

2.

Press the rotary Adjust/Enter control three times in
succession to enter coarse Pre-Set Adjustment.

3.

Press the rotary Adjust/Enter control one more time to enter
fine Pre-Set Adjustment.

4.

Press the rotary Adjust/Enter control once again to set the
value.

The units can also timeout (adjustable) to exit the menu. Once
Pre-Set Mode is entered, CrPU or FnPU will appear in the voltage
display.