Installation

2-6

M370430-01 Rev E

XG 1500 and 1700 Watt AC Input Connector

On the XG family 1U, full 19-inch rack models, the AC input connector
is a 3-terminal wire clamp located on the rear panel of the power supply.

Figure 2-1

1500 and 1700 Watt AC Input Cover and Strain Relief

XG 1500 and 1700 Watt AC Input Wire

The full 19-inch rack models are not supplied with a power cord or a
non-locking AC plug. Table 2-2 specifies the recommended AC input
wire size. You must also purchase and install the correctly rated
non-locking plug for your installation.

Make sure that the wiring of the product and the AC plug comply with
the applicable local code for your installation. If you require a special
cord, contact Customer Service (see “Contact Information” on page i).

Table 2-2

XG 1500 and 1700 Watt: Recommended AC Input Wire (higher power)

AC Input Voltage Range and

Frequency

Wire Specifications

85-265 Vac, 47-63 Hz, single
phase 3 wire

3 x 10 AWG (2 wire plus safety
ground, stranded copper, 60 ºC
minimum, 300 V. The input
cord must be no longer than
9.84 feet (3 m).