AMETEK XG Family Programmable DC User Manual

Page 173

Advertising
background image



Remote Operation

M370430-01 Rev E

5-41

5

Table 5-13

OPERation SHUTdown Status Register

Bit

Bit Weight Bit Name

Description

0

1

PROTection

Reflects the summary of the PROTection
sub-register.

1

2

INTerlock

The power supply is shut down by INTerlock signal.

2

4

Not Used

Not Used

3

8

External Shutdown

The power supply is shut down by External Shutdown
signal.

Table 5-14

OPERation SHUTdown PROTection Status Register

Bit

Bit Weight Bit Name

Description

0

1

OVP

Over Voltage protection has tripped.

1

2

UVP

Under Voltage protection has tripped.

2

4

OCP

Over Current protection has tripped.

3

8

Not Used

Not Used

4

16

AC Off

AC failure protection has tripped.

5

32

OTP

Over Temperature protection has tripped.

6

64

Not Used

Not Used

7

128

Foldback

Foldback protection has tripped.

8

256

Fan

Fan failure protection has tripped.