Resetting activated foldback protection – AMETEK XG Family Programmable DC User Manual

Page 72

Advertising
background image



Local

Operation

3-26

M370430-01 Rev E

4.

Press the rotary Adjust/Enter control to commit the setting
once the desired value has been set.

5.

The green FLD LED will turn off and the display will return
to the normal display mode.

The SCPI command (s) for these instructions are:

[:]OUTPut[<channel>]:PROTection:FOLDback[:MODE]

[:]OUTPut[<channel>]:PROTection:FOLDback:LATCh

Important:

If you set foldback while the output is enabled and the trigger you

select is the same as the current operating mode, the foldback timer will begin
counting immediately after the delay time has been set.

Resetting Activated Foldback Protection

To reset activated and latched foldback protection, press and hold the
rotary Adjust/Enter control for approximately 3 seconds.

The SCPI command (s) for these instructions are:

[:]OUTPut[<channel>]:PROTection:CLEar

Advertising