Table A-3

SCPI Commands for Output Control

Function

SCPI Command

Description

Parameter and
Range

Query

Set Current
Sharing Mode

[[:]]SOURce[<channel>]]:COMBine:CSHare
[: MODE]

Set the unit to operate in the
current share controller or
slave mode. If only a single
unit is being used it should be
set to controller.

?|CONTroller
|SLAVe

Yes

Set
(Immediate)
Current Set
point

[[:]SOURce[<channel>]]:CURRent[:LEVel]
[:IMMediate][:AMPLitude]

Set current set point
(immediate)

?|<Current Set
Point>|MAXimum|
MINimum

Yes

Set Constant
Power

1

Set

point

[:]SOURce:POWer:LEVel

Set constant power set point
(immediate)

?|<Power Set Point> Yes

Set Constant
Power Mode

1

[:]SOURce:POWer:MODe

Set constant power mode
(Enable/Disable)

?|ON|OFF

Yes

Set
(Immediate)
Voltage Set
point

[[:]SOURce[<channel>]]:VOLTage[:LEVel]
[:IMMediate][:AMPLitude]

Change voltage set point
(immediate)

?|<Voltage Set
Point>|MAXimum|
MINimum

Yes

Set Over
Voltage
Protection
Level

[[:]SOURce[<channel>]]:VOLTage:PROTect

ion[:OVERvoltage][:LEVel]

Set the over voltage
protection level.

?|<OVP Set
Point>|MAXimum|
MINimum

Yes

Set Under
Voltage
Protection
Level

[[:]SOURce[<channel>]]:VOLTage:PROTect

ion:UNDer[:LEVel]

Set the under voltage
protection level.

?|<UVP Set
Point>|MAXimum|
MINimum

Yes