4

Resistive-Controlled Voltage APG Setup

To activate APG voltage mode using an external resistor:

1.

Turn the 9-position mode control to the VAP position or press
the rotary Adjust/Enter control if the mode control is already
at the VAP position.

is displayed on the output voltage display.

2.

Turn the rotary Adjust/Enter control to select

(resistor

source from non-isolated connector).

3.

Press the rotary Adjust/Enter control to commit the selected

mode.

is displayed on the output voltage display.

4.

Select the input source level using the rotary Adjust/Enter

control.

5.

Once the desired level has been selected, press the rotary

Adjust/Enter control to commit the change.

The display will return to the normal display.

Deactivating APG Voltage Mode

To deactivate the APG voltage mode:

1.

Turn the 9-position mode control to the VAP position or press
the rotary Adjust/Enter control if the mode control is already
at the VAP position.

2.

is displayed on the output voltage display.

3.

Turn the rotary Adjust/Enter control to select

.

4.

Press the rotary Adjust/Enter control to commit the change.

The display will return to the normal display.