Terminal configuration – AMETEK XG Family Programmable DC User Manual

Page 382

Advertising
background image



APPENDIX

E

Lantronix Procedures for MEA Option

E-12

M370430-01 Rev E

3.

Press the rotary Adjust/Enter control.

Α∆∆Ρ

is displayed on the output voltage display.

4.

Turn the rotary Adjust/Enter control to select the desired
address between 1 to 30.

5.

Press the rotary Adjust/Enter control to commit the new
address.

Terminal Configuration

The terminal program allows for communication with the power supply.
To use a terminal program, set it up using the parameters from the
following sections. If you wish to use HyperTerminal, see “Setting Up a
HyperTerminal Connection” below for instructions.

Data Format

Serial data format is 8 bit, one stop bit. No parity bit. Flow control:
none.

End of Message

The end of message is the Carriage Return character (ASCII 13,
0x0D).The power supply ignores the Line Feed (ASCII 10, 0x0A)
character.

Setting Up a HyperTerminal Connection

To set up a HyperTerminal connection:

1.

Start Windows HyperTerminal by clicking Start >All
Program >Accessories > Communications > HyperTerminal.

The New Connection HyperTerminal window appears (Figure
E-14).