Warning: shock hazard – AMETEK XG Family Programmable DC User Manual

Page 108

Advertising
background image



Analog

Programming (APG) and Isolated Analog Programming (ISOL)

4-8

M370430-01 Rev E

Wiring

WARNING: Shock hazard

There is a potential shock hazard at the output when using a power supply with a
rated output greater than 60 V. Use load wiring with a minimum insulation
rating equivalent to the maximum output voltage of the power supply. For
example, select TEW, 105 °C, 600 V wiring for use with a 600 V 1.4 Amp or 2.8
Amp power supply.

For most connectors and jumpers, use any suitable wire such as 20
to 26 AWG stranded wire. For lowest noise performance, use
shielded twisted pair wiring of 20 to 26 AWG of the shortest length
possible. Ground the shield to pin J1.7 (analog common) on the
Analog Programming Connector or to the chassis via one of the
Analog Programming Connector screws.