Non-isolated Current Monitoring Calibration

Important:

For maximum accuracy at a specific APG level, follow the

calibration procedure again but use the intended operating voltage level in steps
3 and 9.

To calibrate the non-isolated current monitoring:

1.

Short the main output with a shunt. Connect a multimeter to
measure the voltage across the shunt.

2.

Connect the voltmeter to the non-isolated current monitoring

output lines (J1.12 - J1.7).

3.

Set the Current APG level to 4 V. Send the SCPI command:

SYST:COMM:APR:LEV:CURR 4

4.

Set the input source as Local.

5.

The SCPI command is:

SYST:REM:SOUR:CURR LOC

6.

Set the main output voltage to 100% by sending the command

SOUR: VOLT <ModelVolt> or use the rotary adjust/Enter
control.

7.

Turn the main output On by pressing the OUTPUT ENABLE

Main button on the front panel or send the command:

:OUTP ON

The OUTPUT ENABLE Main button will illuminate.

8.

Enter interactive calibration mode by sending SCPI

command:

CAL:MON:CURR

9.

Press on the terminal keys - or + to reduce or increase the

monitoring value. Adjust the monitoring value displayed on
the voltmeter that was set up in Step 1 to read as close as
possible to 4.000 V.

10.

Press any key other than the + or - keys to exit from

interactive calibration mode.