Analog

Programming (APG) and Isolated Analog Programming (ISOL)

4-4

M370430-01 Rev E

Auxiliary Outputs

The auxiliary outputs are an additional isolated source. The
auxiliary output has two outputs: +5 V output on J3.9 and a +15 V
output on J3.11. The auxiliary output operates independently of the
main output. It is enabled or disabled from the front panel by
pressing the OUTPUT ENABLE Aux button. When the Aux
output is enabled, the OUTPUT ENABLE Aux button is
illuminated. Like the main output of the power supply, the Aux
also has the ability to Autostart at power up. See “Output Auto
Start Mode (Auto Restart)” on page 3-17 and “Auxiliary Auto Start
Mode” on page 3-18 for details on controlling this feature.

Table 4-2 provides a summary of the options available for
programming output voltage and current set point using an analog
source.

Table 4-2 Remote Programming Options

Control of...

Programming Scale

1

For more
info...

Output voltage

2-10 V Voltage source (adjustable)

See page 4-10.

Current set point

2-10 V Voltage source (adjustable)

See page 4-12.

Output voltage

2-10 kΩ Resistive source (adjustable)

See page 4-15.

Current set point

2-10 kΩ Resistive source (adjustable)

See page 4-17.

1. The resolution can be adjusted in increments of 0.1 volts.