AMETEK XG Family Programmable DC User Manual

Page 172

Advertising
background image



Remote

Operation

5-40

M370430-01 Rev E

Table 5-12

OPERation Status Register

Bit

Bit Weight Bit Name

Description

0

1

CALibrating

Indicates that the supply is in CALibration Mode.

1

2

SETTling

Not implemented

2

4

RANGing

Not implemented

3

8

SWEeping

Not implemented

4

16

MEASuring

Not implemented

5

32

Waiting for Arm

Not implemented

6

64

Waiting for Trigger

Not implemented

7

128

CORRecting

Not implemented

8

256

Not Used

Not Used

9

512

SHUTdown Summary

Reflects the summary of the SHUTdown
Sub-Register.

10

1024

Local Lockout

Front panel lockout

11

2048

Current Share Summary

Reflects the summary of the CSHare Sub-Register.

12

4096

Constant Voltage Mode

Reflects the output mode of the supply.

13

8192

Constant Current Mode

Reflects the output mode of the supply.

14

16384

Program Running

Indicates if an Autosequence program is currently
running.

The operation shutdown status register describes the cause of the power
supply shutting down the output. More than one bit may be active and
multiple actions will be required to restart the unit. The protection
shutdown sub-register indicates which protection mechanisms have
caused the power supply to shutdown.