Analog Programming

(APG) and Isolated Analog Programming (ISOL)

M370430-01 Rev E

4-31

4

Query for ISOL Current Input Level

To query for ISOL current input level from non-isolated input:

1.

Turn the 9-position mode control to the CAP position or press
the rotary Adjust/Enter control if the control knob is already
at the CAP position.

is displayed on the output voltage display.

2.

If the mode is currently

then select any other ISOL

mode. If this step is done, be sure to restore the ISOL setting
to

when the operation is complete. Otherwise, do not

rotate the rotary Adjust/Enter control to keep the current
ISOL mode.

3.

Press the rotary Adjust/Enter control to select the ISOL mode.

The output voltage display should read

and the output

current display will display ISOL level.

4.

Press the rotary Adjust/Enter control to return to normal

mode.

5.

If the ISOL mode was modified in step 2, execute the

procedure to deactivate the ISOL voltage mode.

Quick Tip Remote
operation uses these
SCPI commands. See
page 5-1.

The SCPI command for these instructions are:

[:]SYSTem[<channel>]:REMote:SOURce:CURRent <?|LOCal
|AVOLtage|IAVoltage|ARESistive|IAResistive>

[:]SYSTem[<channel>]:COMMunicate:APRogram:LEVel:CURRent
[:ISOlated]

[:]MEASure[<channel>][:SCALar]:APRogram:CURRent
:ISOlated[:DC]?