Configuring remote control using rs-485, Caution: equipment damage – AMETEK XG Family Programmable DC User Manual

Page 139

Advertising
background image



Remote Operation

M370430-01 Rev E

5-7

5

Configuring Remote Control Using RS-485

RS-485 Communication Cable with RJ-45 to DB-9

Communication control cable with DB-9 pinout (female) on the PC side
(see Figure 5-2) and RJ-45 shielded connector on the power supply.

CAUTION: Equipment damage

Figure 5-5 shows an example of wiring for NI RS485 communication
cable with DB-9. Refer to the user manual of your communication card
before wiring the cable.

Table 5-5 DB-9 Pinouts

Pin

Name

Description

1

GND

Ground

2, 3

NC

No connection

4

RXD+

Receive data

Twisted
pair

5

RXD-

Transmit data

6, 7

NC

No connection

8

TXD+

Transmit data

Twisted
pair

9

TXD-

Transmit data

Table 5-6 RJ-45 Plug Pinouts

Pin

Name

Description

1, 2

NC

No connection

3

TXD+

Transmit data

Twisted
pair

4

TXD-

Transmit data

5

RXD+

Receive data

Twisted
pair

6

RXD-

Receive data

7

GND

Ground

8

NC

No connection

DB-9 connector on PC

RJ-45 plug

Figure 5-5

RS-485 Communication Cable with DB-9

TXD+
RXD+
TXD–
RXD–

GND

TXD+
TXD–
RXD+
RXD–

Advertising