AMETEK XG Family Programmable DC User Manual
Page 319
M
3
7
0
4
3
0
-0
1
R
e
v
E
A
-2
7
A
A
P
P
E
N
D
IX
A
S
C
P
I C
o
m
m
a
n
d
R
e
fe
re
n
c
e
Table A-9
System Commands (Continued)
Set Alarm
Output Latches
[:]SYSTem[<channel>]:PROTection:LATCh
Sets the Alarm Output
Latches. See Table 3-6 on
page 3-24.
?| <Sum of output latch
flags>
Yes
Table A-10
Status Commands
Function
SCPI Command
Description
Parameter and
Range
Query
Query
Operation
Status
Condition
Register
[:]STATus[<channel>]:OPERation :CONDit
ion?
Query the Operations
Condition Register. See
Table 5-11 on page 5-36.
Yes
Set Operation
Status Enable
Register
[:]STATus[<channel>]:OPERation:ENABle
Access the Operations Enable
Register. See Table 5-11 on
page 5-36.
?|<Enable Flags
-(0–65535)>
Yes
Query
Operation
Status Event
Register
[:]STATus[<channel>]:OPERation[:EVENt]
?
Query the Operations Event
Register. See Table 5-11 on
page 5-36.
Yes
Set Operation
Status
Negative
Transition
Register
[:]STATus[<channel>]:OPERation
:NTRansition
Access the Operation
Negative Trans Filter
Register. See Table 5-11 on
page 5-36.
?|<Transition Flags -
(0–65535)>
Yes