VOLTage Sub-Register

This shows whether the present voltage level is over or under the
specified trip limit.

Table 5-17

QUEStionable VOLTage Status Register

Bit

Bit Weight Bit Name

Description

0

1

OVP

Over Voltage Protection

1

2

UVP

Under Voltage Protection


TEMPerature Sub-Register

This shows whether the temperature of critical components is near or
over the maximum operating temperature.

Table 5-18

QUEStionable TEMPerature Status Register

Bit

Bit Weight

Bit Name

Description

0

1

OTP

Over Temperature Protection

Reading Internal Temperature Measurements

Internal temperatures are measured by the channels of a fan controller.
The XG 850 has one fan controller, Fan0, with two channels, 0 and 1,
that each control a fan and measure temperature. The XG 1700 has two
fan controllers, Fan0 with two channels, 0 and 1, and Fan1 with two
channels, 0 and 1 (four fans total).

The SCPI command (s) for these readings are:

DIAGnostic:MEMory:FAN<n>:READ #h0<n>

Example: to read the temperatures in the XG 850,

DIAG:MEM:FAN0:READ #h00

//this reads the 1st channel

DIAG:MEM:FAN0:READ #h01

//this reads the 2nd channel

To read temperatures in the XG 1700 send either or both of the above
example commands for the channel(s) of the first fan, and input

FAN1

in

place of

FAN0

to read the temperature measurements taken by the

channel(s) of the second fan.