Mmi instrument physical addresses – Super Systems SuperDATA User Manual

Page 31

Advertising
background image

Super Systems Inc

Page 31 of 172

Super Data Operations Manual

setup.

ALM(PAL slot, Alarm offset, Alarm Bitmap Start Slot, Alarm ACK

Bitmap Slot, Number of Bitmap Slots).

e.g., ALM(36,0,0,0,0) for standard

Dualpro

e.g. ALM(36,400,60,64,4) for a Dualpro with Bitmapped alarm

support. Bitmapped alarm support is a custom feature in the Dualpro and is
implemented by some Dualpro programs. Normally this will be configured by
SSI personnel familiar with the DualPro programs. If you are not sure, do not
include Bitmapped support. Invalid configurations may cause spurious invalid
alarms to be reported on RealTime and in AlarmReports.

NOLOG

Optional. Applies to ALL instruments.

Do not log data from this channel.

Include this when communications are required for real-time data but are not
required for historical data logging. If this is not included, the channel will be
data logged at one minute intervals.

ABC

Optional. Applies to ALL instruments.

Alarm Block Configuration .

Caution:

any specified channel can use either ALM or ABC but not both.

Allows a custom

Alarm Block Bitmap (one word) to be setup for any instrument but generally
used only for non-programmable instruments that are not capable of
maintaining alarm bitmaps. See the section on Custom Alarm Block
Configuration.

TAG

Required. Applies to ALL instruments.

Instrument name. Limited to 12

Characters with no spaces.




MMI Instrument Physical Addresses

The physical address is made up from the instruments address (1-15) , the Commux bank (if used) and an optional
table number. The address takes the form (CCC-TT) where CCC = channel and TT = table.

The table is optional and is only used with DUALPRO & MMIGEN type instruments. The table may be 1-31
corresponding to the Dualpro's slave tables. The channel is derived from the instrument address and the
communications bank. If a MMI UCON is used, 15 physical channels are available and the bank is always assumed
to be 0. If a MMI COMMUX is used, 120 physical channels are available, 15 on each of 8 banks.

When a MMI COMMUX is used, construct the channel address as follows:

COMMUX

BANK

1

2

3

4

5

6

7

8

ADDR 01

1

17

33

49

65

81

97

113

ADDR 02

2

18

34

50

66

82

98

114

ADDR 03

3

19

35

51

67

83

99

115

ADDR 04

4

20

36

52

68

84

100

116

ADDR 05

5

21

37

53

69

85

101

117

ADDR 06

6

22

38

54

70

86

102

118

ADDR 07

7

23

39

55

71

87

103

119

ADDR 08

8

24

40

56

72

88

104

120

ADDR 09

9

25

41

57

73

89

105

121

ADDR 10

10

26

42

58

74

90

106

122

ADDR 11

11

27

43

59

75

91

107

123

ADDR 12

12

28

44

60

76

92

108

124

ADDR 13

13

29

45

61

77

93

109

125

ADDR 14

14

30

46

62

78

94

110

126

ADDR 15

15

31

47

63

79

95

111

127

Note: If you view the physical channel as a Hex value, the left digit is (bank-1) and the right digit is the instrument
address.

e.g. bank 5 address 12 = physical channel 76 = x4C.

or physical channel 86 = x56 = bank 6 address 6.

Hex is a more convenient way of viewing the address when using a COMMUX board

.