Alarm Configuration

Introduction to Alarm

Sampling and Alarms

Sampling means the system retrieves statistics data at the sampling interval

At the alarm monitor interval, the system samples the alarm variables and will trigger an alarm if the
value of a variable exceeds its alarm threshold. Alarm information can be output to the network
management system or alarm buffer by configuring the information center.

The alarms can be global alarms, OLT port alarms, or ONU port alarms.

When an alarm configuration command is executed in FTTH view, the command takes effect on
all the OLT ports and all the ONUs attached to the OLT ports.

When an alarm configuration command is executed in OLT port view, the command takes effect
on the current OLT port and all the ONUs attached to the OLT port.

When an alarm configuration command is executed in ONU port view, the command takes effect
only on the ONU corresponding to the current ONU port.

Alarm Configuration Task List

Complete the following tasks to configure alarms:

Task

Remarks

Enabling Alarm Monitoring

Optional

Configuring Global Alarms

Optional

Configuring Alarms on an OLT Port

Optional

Alarm
configuration

Configuring Alarms on an ONU Port

Optional

Displaying and Maintaining Alarm Configurations

Optional

Enabling Alarm Monitoring

Alarm monitoring function takes effect only when statistics sampling function is enabled. This is
because no alarm information can be generated without the average value of sampled statistics.

Follow these steps to enabling sampling and alarm monitoring function:

To do...

Use the command...

Remarks

Enter system view

system-view

Enter FTTH view

ftth