6-6

To do...

Use the command...

Remarks

Enable the error frame seconds

summary alarm function

alarm oam

error-frame-seconds-summary

enable

Optional

The system generates an error

frame seconds summary alarm

when the number of error frame

seconds (in an error frame second,

at least one error frame occurs) in

a specific time period (for example,

1 minute) exceeds the

corresponding predefined

threshold.

By default, this function is enabled.

Configure the window size and

threshold for error frame seconds

summary alarms

alarm oam

error-frame-seconds-summary

{ window window | threshold

threshold

} *

Optional

By default, the window size is 600

(in unit of 100 ms), and the alarm

threshold is 1 second.

Enable the error symbol period

alarm function

alarm oam error-symbol-period

enable

Optional

The system generates an error

symbol period alarm when the

number of error frames in a

specific period (that is, the window

size) exceeds the corresponding

predefined threshold.

By default, this function is enabled.