6-4

To do...

Use the command...

Remarks

Enable the local stable alarm

function

alarm local-stable enable

Optional

The system generates a local

stable alarm when an ONU misuse

occurs in the system, for example,

when an OAM 2.0 ONU and an

OAM 3.3 ONU are mixed in the

same system. (All ONUs in the

same system must adopt the same

OAM version). This alarm is

generated at the OLT side.

By default, this function is enabled.

Enable the critical event alarm

function

alarm oam critical-event enable

Optional

The system generates a critical

event alarm when one of the

following critical events occurs:

local link fault and dying gasp.

Enable the dying gasp alarm

function

alarm oam dying-gasp enable

Optional

The system generates a dying

gasp alarm when a system error, a

data loading error, or any other

nonreversible errors occur.

Enable the error frame period

alarm function

alarm oam error-frame-period

enable

Optional

The system generates an error

frame period alarm when the

number of error frames in a

specific period (that is, the window

size) exceeds the corresponding

predefined threshold.

By default, this function is enabled.