Begin cpr following local medical protocols, 1 select defib – ZOLL R Series Monitor Defibrillator Rev J User Manual

Page 408

Advertising
background image

C

HAPTER

3

M

ANUAL

D

EFIBRILLATION

3–2

www.zoll.com

9650-0912-01 Rev. K

Begin CPR Following Local Medical Protocols.

Request additional assistance.

1 Select DEFIB

Turn the Mode Selector to DEFIB. The unit automatically defaults to 120 joules or the
preconfigured first shock energy selection.

Note:

Defibrillator PADDLES are selected as the ECG source when the instrument is turned
to MONITOR or DEFIB with paddles connected to the OneStep cable.

Energy Select

Look at the Display and verify the energy is appropriate. Unless internal handles are connected
to the OneStep cable, the default energy selections for adult patients are:

Shock 1 - 120 joules

Shock 2 - 150 joules

Shock 3 - 200 joules

If medical protocol allows, you may select a different energy level using the up and down arrow
buttons. One pair is located on the front panel of the unit; the other pair is located on the
sternum paddle.

Note:

Neonatal and pediatric defibrillator energy levels should be selected based on site-
specific protocols.

1

RECORDER

DEFIB

OFF

MONITOR

PACER

3

SHOCK

SHOCK

ENERGY

SELECT

ENERGY

SELECT

ANALYZE

ANALYZE

CHARGE

CHARGE

2

1

or

or

Advertising