In the following example, one DriveLogix controller communicates with a
Logix5550 controller and a ControlNet PLC-5 controller over ControlNet.

Example 3: Sending MSG instructions

You configure a MSG instruction to a Logix5550 controller the same as you
do for a DriveLogix controller. All Logix-based controllers follow the same
MSG configuration requirements. See Example 2 above.

Configuring a MSG instruction for a PLC-5 controller depends on the
originating controller.

For MSG instructions originating from the DriveLogix controller to the
ControlNet PLC-5 controller:

DriveLogix controller
(DriveLogix1)

ControlNet

ControlLogix controller
(Control1)

ControlNet PLC-5 controller
(PLC5C1)

DriveLogix controller
(DriveLogix2)

Distributed control with a
ControlLogix controller as the
coordinating controller

Type of Logix MSG instruction:

Source:

Destination:

Typed Read

any integer element (such as B3:0,
T4:0.ACC, C5:0.ACC, N7:0, etc.)

SINT, INT, or DINT tag

any floating point element (such as F8:0,
PD10:0.SP, etc.)

REAL tag