Publication 20D-UM002C-EN-P - November 2003

3-12 Placing and Configuring the Drive

Not all 32-bits within parameter 151 [Logic Command], are directly visible in
the PowerFlex 700S. To view all 32-bits, refer to parameter 152 [Applied
LogicCmd].

DriveLogix Controller Outputs

PowerFlex 700S Inputs

Tag Name

Data
Type

Parameter Linked

Parameter

Number

Name

Name

Number

drive_module:O.LogicCommand

DINT

600

Integer In00

Applied LogicCmd

152

drive_module:O.SpdRampDsbl

BOOL

bit 0

Integer In00

SpdRamp Dsbl

bit 0

drive_module:O.SpdSCrvEn

BOOL

bit 1

Integer In00

Spd S Crv En

bit 1

drive_module:O.TachLossRst

BOOL

bit 2

Integer In00

TachLoss Rst

bit 2

drive_module:O.TimeAxisEn

BOOL

bit 3

Integer In00

Time Axis En

bit 3

drive_module:O.MCAtuneEn

BOOL

bit 4

Integer In00

MC Atune En

bit 4

drive_module:O.DirCtrlEn

BOOL

bit 6

Integer In00

Dir Sel En

bit 6

drive_module:O.PMOffsetEn

BOOL

bit 7

Integer In00

PM Offset En

bit 7

drive_module:O.MtrInertEn

BOOL

bit 8

Integer In00

Mtr Inert En

bit 8

drive_module:O.SysInertEn

BOOL

bit 9

Integer In00

Sys Inert En

bit 9

drive_module:O.InertiaComp

BOOL

bit 10

Integer In00

Inertia Comp

bit 10

drive_module:O.FrictComp

BOOL

bit 11

Integer In00

Frict Comp

bit 11

drive_module:O.ProcsTrimEn

BOOL

bit 12

Integer In00

ProcsTrim En

bit 12

drive_module:O.PositionEnbl

BOOL

bit 13

Integer In00

PositionEnbl

bit 13

drive_module:O.NormalStop

BOOL

bit 16

Integer In00

Normal Stop

bit 16

drive_module:O.Start

BOOL

bit 17

Integer In00

Start

bit 17

drive_module:O.Jog1

BOOL

bit 18

Integer In00

Jog 1

bit 18

drive_module:O.ClearFault

BOOL

bit 19

Integer In00

Clear Fault

bit 19

drive_module:O.UnipolFwd

BOOL

bit 20

Integer In00

Unipol Fwd

bit 20

drive_module:O.UnipolRev

BOOL

bit 21

Integer In00

Unipol Rev

bit 21

drive_module:O.Jog2

BOOL

bit 23

Integer In00

Jog 2

bit 23

drive_module:O.CurrLimStop

BOOL

bit 24

Integer In00

CurrLim Stop

bit 24

drive_module:O.CoastStop

BOOL

bit 25

Integer In00

Coast Stop

bit 25

DriveLogix Controller Outputs

PowerFlex 700S Inputs

Tag Name

Data
Type

Parameter Linked

Parameter

Number

Name

Name

Number

drive_module:I.LogicStatus

DINT

600

Integer In00

Logic Status

155

drive_module:I.Enabled

BOOL

bit 0

Integer In00

Enabled

bit 0

drive_module:I.Running

BOOL

bit 1

Integer In00

Running

bit 1

drive_module:I.CommandDir

BOOL

bit 2

Integer In00

Command Dir

bit 2

drive_module:I.ActualDir

BOOL

bit 3

Integer In00

Actual Dir

bit 3

drive_module:I.Accelerating

BOOL

bit 4

Integer In00

Accelerating

bit 4

drive_module:I.Decelerating

BOOL

bit 5

Integer In00

Decelerating

bit 5

drive_module:I.Jogging

BOOL

bit 6

Integer In00

Jogging

bit 6

drive_module:I.Faulted

BOOL

bit 7

Integer In00

Faulted

bit 7

drive_module:I.Alarm

BOOL

bit 8

Integer In00

Alarm

bit 8

drive_module:I.FlashMode

BOOL

bit 9

Integer In00

Flash Mode

bit 9

drive_module:I.RunReady

BOOL

bit 10

Integer In00

Run Ready

bit 10

drive_module:I.AtLimit

BOOL

bit 11

Integer In00

At Limit

bit 11

drive_module:I.TachLossSw

BOOL

bit 12

Integer In00

Tach Loss Sw

bit 12

drive_module:I.AtZeroSpd

BOOL

bit 13

Integer In00

At Zero Spd

bit 13

drive_module:I.AtSetptSpd

BOOL

bit 14

Integer In00

At Setpt Spd

bit 14

drive_module:I.AtSetpt1

BOOL

bit 16

Integer In00

At Setpt 1

bit 16

drive_module:I.AboveSetpt2

BOOL

bit 17

Integer In00

Above Setpt2

bit 17

drive_module:I.MCEnAck

BOOL

bit 28

Integer In00

MC En Ack

bit 28

drive_module:I.MCCommis

BOOL

bit 19

Integer In00

MC Commis

bit 19

drive_module:I.SpdCommis

BOOL

bit 20

Integer In00

Spd Commis

bit 20

drive_module:I.TorqueMode

BOOL

bit 22

Integer In00

Torque Mode

bit 22

drive_module:I.SpeedMode

BOOL

bit 23

Integer In00

Speed Mode

bit 23

drive_module:I.PositionMode

BOOL

bit 24

Integer In00

PositionMode

bit 24

drive_module:I.StartActive

BOOL

bit 25

Integer In00

Start Active

bit 25

drive_module:I.CommandRun

BOOL

bit 26

Integer In00

Command Run

bit 26