What Is DriveLogix? 2-21

You can select:

After you load or store to or from nonvolatile memory, RSLogix 5000 software
goes offline from the controller.

For details on storing to nonvolatile memory or restoring from nonvolatile
memory, see the Logix5000 Controllers Common Procedures Programming Manual,
publication 1756-PM001.

3.

Click the Load/Store button and specify when you want the controller to load the project from nonvolatile memory.

4.

Click the Load button to load the project from nonvolatile memory into the controller.

In this field:

Select this option:

If you want:

Load Image

On Power Up

to load memory when you turn on or cycle the chassis
power

On Corrupt Memory

to load memory whenever there is no project in the
controller and you turn on or cycle the chassis power

User Initiated

only use RSLogix 5000 software to load a project

Load Mode

Remote Program

the controller to go to Remote Program mode after
loading from nonvolatile memory

Remote Run

the controller to go to Remote Run mode after loading
from nonvolatile memory