What Is DriveLogix? 2-17

the controller. However, the controller can use a MSG instruction to get
information directly to or from a DeviceNet device.

Determining Total
Connection Requirements

To calculate the total connection requirements for a DriveLogix controller,
consider the connections to local I/O modules, the host PowerFlex 700S drive
and the connections to remote modules.

Use the following table to tally local connections:

Regardless of how you configure the I/O modules (rack-optimized or direct
connect) on the local rail, the controller establishes a rack-optimized
connection for the rail. The data for any I/O module configured for a
rack-optimized connection is stored in the rack-optimized connection for the
rail. You can have 8 I/O modules, for a maximum of 8 direct connections.

Connection Type:

Device
Quantity:

Connections
per Device:

Total
Connections:

connection to host PowerFlex 700S drive

1

1

1

rack-optimized connection for the local DIN rail

2

1

2

I/O module (rack-optimized connection) on local rail

0

I/O module (direct connection) on local rail

1

1788-CNx ControlNet communication card

0

0

1788-DNBO communication card (rack-optimized connection)

2

1788-ENBT Ethernet/IP communication card

0

0

total