Publication 20D-UM002C-EN-P - November 2003

Placing and Configuring the Drive 3-11

Table 3.5 Mapping for the Custom User-Defined Control Communication Format

For each of the communication formats, drive_module:O.LogicCommand and
drive_module:I.LogicStatus are provided as DINT data types. In addition to
these tags, the control bits for each are also available as Boolean values with tag
names that correspond to the control bits in the drive. This gives you the
option of programming the Logic Command and Status words at the Boolean
level or as an integer value.

DriveLogix Controller Outputs

PowerFlex 700S Inputs

Tag Name

Data
Type

Parameter

Linked Parameter

Number

Name

Name

Number

drive_module:O.LogicCommand

DINT

600

Integer In00

Logic Command

151

drive_module:O.UserDefinedRealData[0]

REAL

603

Real In01

drive_module:O.UserDefinedRealData[1]

REAL

605

Real In02

drive_module:O.UserDefinedRealData[2]

REAL

607

Real In03

drive_module:O.UserDefinedRealData[3]

REAL

609

Real In04

drive_module:O.UserDefinedRealData[4]

REAL

611

Real In05

drive_module:O.UserDefinedRealData[5]

REAL

613

Real In06

drive_module:O.UserDefinedRealData[6]

REAL

615

Real In07

drive_module:O.UserDefinedRealData[7]

REAL

617

Real In08

drive_module:O.UserDefinedIntegerData[0]

DINT

618

Integer In09

drive_module:O.UserDefinedIntegerData[1]

DINT

620

Integer In10

drive_module:O.UserDefinedIntegerData[2]

DINT

622

Integer In11

drive_module:O.UserDefinedIntegerData[3]

DINT

624

Integer In12

drive_module:O.UserDefinedIntegerData[4]

DINT

626

Integer In13

drive_module:O.UserDefinedIntegerData[5]

DINT

628

Integer In14

drive_module:O.UserDefinedIntegerData[6]

DINT

630

Integer In15

DriveLogix Controller Inputs

PowerFlex 700S Outputs

Tag Name

Data
Type

Parameter

Linked Parameter

Number

Name

Name

Number

drive_module:I.LogicStatus

DINT

632

Integer Out00

Logic Status

155

drive_module:I.UserDefinedRealData[0]

REAL

635

Real Out01

drive_module:I.UserDefinedRealData[1]

REAL

637

Real Out02

drive_module:I.UserDefinedRealData[2]

REAL

639

Real Out03

drive_module:I.UserDefinedRealData[3]

REAL

641

Real Out04

drive_module:I.UserDefinedRealData[4]

REAL

643

Real Out05

drive_module:I.UserDefinedRealData[5]

REAL

645

Real Out06

drive_module:I.UserDefinedRealData[6]

REAL

647

Real Out07

drive_module:I.UserDefinedRealData[7]

REAL

649

Real Out08

drive_module:I.UserDefinedIntegerData[0]

DINT

650

Integer Out09

drive_module:I.UserDefinedIntegerData[1]

DINT

652

Integer Out10

drive_module:I.UserDefinedIntegerData[2]

DINT

654

Integer Out11

drive_module:I.UserDefinedIntegerData[3]

DINT

656

Integer Out12

drive_module:I.UserDefinedIntegerData[4]

DINT

658

Integer Out13

drive_module:I.UserDefinedIntegerData[5]

DINT

660

Integer Out14

drive_module:I.UserDefinedIntegerData[6]

DINT

662

Integer Out15

Advertising