Cutout – Rockwell Automation 2711E-xxxx PanelView Operator Terminals User Manual User Manual
Page 36
Advertising
![background image](/manuals/580602/36/background.png)
2–5
Installing PanelView 1000e Terminals
Publication 2711E-821 – January 1998
Figure 2.4 Clip-Mount Touch Screen Terminal Panel
Cutout
24756
14.58
”
(370 mm)
13.29
”
(338 mm)
11.11
”
(282 mm)
Bezel Border Line
CUTOUT
CL
CL
10.11
”
(257 mm)
Eight assembled mounting clips are provided with the clip-mount
touch screen terminals; only six clips are used for the mount.
To install the clips:
1. Make sure the gasket is installed. If not, NEMA 4X will not be
met.
2. Install the six mounting clips (2 on top, 2 on bottom, 1 on each
side). The ends of the clips slide into the slots on the terminal.
3. Tighten the mounting clip screws by hand until the gasket seal
contacts the mounting surface uniformly. See Figures 2.5 and 2.6
for details.
Advertising