Installing PanelView 1200e Terminals

Publication 2711E-821 – January 1998

Mounting a Stud-Mount Keypad Terminal in a 19-inch Rack

You can mount a PanelView 1200e Stud-Mount Keypad terminal in a
standard EIA 19-inch rack. No additional hardware is required.

To mount the terminal:

1. Place the terminal in the rack, aligning the studs with the holes in

the rack.

2. Insert the terminal until the gasket material is flush with the wall

cutout or panel.

3. Nuts are provided with the stud-mount terminal models. Tighten

the nuts to compress the gasket on the terminal.

Built-in spacers prevent the gasket from being over-compressed. The
tightening torque increases significantly when you reach the correct
compression. At this point the tightening torque should not exceed
10 inch-pounds.

Mounting a Touch Screen Terminal in a 19-inch Rack

To mount the PanelView 1200e Clip-Mount or Stud-Mount Touch
Screen terminals in a standard 19-inch EIA rack, you need a Rack
Mount Kit (A-B Catalog Number 2711-NR1). This kit consists of a
rack adapter and mounting hardware.

You have several options for setting up the terminal. Figure 3.1
shows the locations of the options described in the remainder of this
chapter.

Adjusting Contrast and Brightness

The Contrast and Brightness Controls adjust the terminal display
intensity and contrast. The terminal display is set at the factory.

To increase terminal contrast and brightness:

"

Turn the controls clockwise.

To decrease terminal contrast and brightness:

"

Turn the controls counter-clockwise.

Setting Up the PanelView
1200e Terminal